1(815) 344-3100

Embedded Concrete-Rubber (ECR) Specifications:

Embedded Concrete-Rubber (ECR) Cross Section View:

Panel Lengths:

  • 8’, 8’-1 1/2”, 9’ and 10’

Panel Height:

  • Accomdates 115# to 141# Rail

Gauge Panel Width:

  • 50 1/2 inches

Field Panel Width:

  • 27 inches (10-foot tie)

  • 21 inches ( 9-foot tie)

Fastners:

  • Timber Screws, 3/4” x 12”

  • Medium Carbon Steel

  • Tensile Strength 120,000 psi Min.

  • Pullout Resistance +13,000 lbs

Concrete:

  • Compressive Strength: 6000 p.s.i.

  • Entrained Air: 6.0 % ± 1%

  • Max. Water/Cement Ratio: 0.44 %

  • Salt Sealer: Co-Ma-Seal CM

Rebar:

  • ASTM A615 Gr.60 (Tied)

  • ASTM A706 Gr.60 (Welded)

Steel Angle:

  • ASTM A36

Field Rubber:

  • Type: Virgin SBR

  • Tensile: 2,000 p.s.i.

  • Hardness: 65 ± 5 Durometer

  • Shore A

  • Elongation: 400%

Gauge Rubber:

  • Type: EPDM

  • Tensile: 850 p.s.i.

  • Hardness: 75 ± 5 Durometer

  • Shore A

  • Elongation: 400%